Romero, Gómez-Salgado, Romero-Arana, and Ruiz-Frutos: Utilization of a healthcare failure mode and effects analysis to identify error sources in the preanalytical phase in two tertiary hospital laboratories

Introduction

Although the presence of errors in the healthcare environment is a perfectly known risk both by patients and professionals, its existence implies the need to take into consideration actions for achieving the principle “primus non nocere” and avoiding harmful situations for the population (1).

In our country, the prevalence of adverse effects in primary care centers (PCC) was explained in the Patient Safety in Primary Health Care Study (in Spanish), which addressed patient safety in Spanish primary health care facilities and described that every 9.6 visits of 1000 will produce an adverse effect on the patient in PCC attention, although its degree of seriousness will be low (2).

On the other hand, the presence of errors in the preanalytical phase has been a widely studied topic in recent years. Several strategies have been developed as research lines, and actions have been set up in order to minimize the impact of these errors, studying their importance in different areas of the preanalytical phase in and out of the laboratory (3-8).

It is highly important to consider that the lack of detection or the misdetection of these errors can cause a potential risk, leading to misdiagnosis or wrong assessment in the patients’ follow-up. These errors could become serious, so their correct management is essential. Thus, the utilization of procedures that lead us to use diverse methodology is necessary, combining the detection of errors and the searching of the possible sources that may allow planning both preventive and corrective actions. In this sense, clinical laboratories have been characterized by an innovative profile that pursues the quality of their products introducing concepts such as quality control, quality assurance, or quality management (9).

Although the Failure Mode and Effects Analysis (FMEA) was first applied by the aerospace industry in the 1960s, and is usually employed in the analysis of a product or process, this method is valid for any kind of process or situation (10). Its adaptation to healthcare, Healthcare Failure Mode and Effect Analysis (HFMEA), was done by the US Veteran Health Administration and the Joint Commission on the Accreditation of Health Care at the end of the 1990s (11).

In this way, several studies have used the HFMEA as a useful tool to identify potential sources of errors and their possible causes and to take action to prevent them in the preanalytical phase with the previously stated aim (12, 13).

In addition, although this aspect is not much developed in the literature, the role played by nurses and auxiliary staff is relevant, but they are not usually included in these studies. Despite this, it must be noted that nurses are in charge of the biological samples collection procedure, right in the heart of the preanalytical phase, and the auxiliary and support staff are key in its development. Several works have verified the importance of this role, insisting on the need of improvement in samples identification or in specific training, not always obtaining good results, although the relevance of this role has in fact been made evident as for the improvement of the patient safety (14-16).

The previously mentioned studies that used HFMEA have been performed in regional hospitals of our public healthcare system which have specific characteristics that could lead to a better control of the external factors such as the distance from the collection to the delivery point of samples (10, 11).

In the current study, the results of two HFMEA are presented, developed in laboratories from our health regional system that receive samples from PCC and that are located at a greater distance from the sampling points. In addition, they include other considerations that might imply the relevance of a procedure of these characteristics.

Therefore, we hypothesized that obtaining data from those involved in the preanalytical phase could provide complete and useful information to develop improvement programs that can help enhance the detection of errors, decreasing their number.

Thus, the aim of this study is to improve the ability to identify error sources with the use of HFMEA as a tool during the preanalytical phase in samples from the PCC that arrive at the laboratories of two tertiary hospitals.

Materials and methods

Study design

We performed a descriptive study by means a HFMEA with the determination of the Risk Priority Number (RPN) of every item. The study was performed between April and October 2016.

Participants

We included data obtained from two laboratories of the Andalusian public healthcare system: Virgen de la Victoria (Málaga, LAB1) and Juan Ramón Jiménez (Huelva, LAB2). Both centers receive samples from PCC to their areas, and both have a similar structure in preanalytical and samples reception areas.

LAB1 processes approximately 890,000 blood and urine samples yearly provided by PCC, and LAB2 receives 580,000 (data from 2015). Both laboratories receive samples from PCC located at a similar distance, use similar transportation and refrigeration means, and also have the same sample reception areas structure. The difference between samples is due to the different population of the areas (population in the province of Malaga is larger than in Huelva).

The first step was, by means of the analysis of the process of study and a brainstorm by our research team, to develop a scheme based on the preanalytical phase in which the different steps of the process where errors could appear were described. This scheme included six key areas that might be considered potential error sources in the preanalytical phase: analytical request and request form, appointment system, patient preparation, sampling, transport, and reception - preparation of samples. Then, we summoned the participants in order to proceed as has been previously described.

A group of professionals was set up, including two nurses (from PCC and laboratories), two laboratory technicians, two support staff and three doctors (2 analysts and 1 general practitioner), who were informed in detail of the purpose of the study and the methodology to use. Each group was coordinated by a member of the research team (in LAB1, the coordinator of the group was a clinical chemist, while in LAB2 the coordinator was a laboratory specialized nurse).

Data presentation

Every participant was invited to comment on relevant aspects about the possible error sources they identified, following the order of the previously designed scheme, and they were asked to give a score from 1 to 10 for the severity rate (SR) and the occurrence rate (OR), being in both cases 10 the indicator of maximum rate, and to score the detection rate (DR), that values the capacity of being detected, with an inverse scale (higher probability of detection, lower numerical value). The RPN was calculated by multiplying the three data resulting (SR x OR x DR = RPN), then following a Pareto chart (17).

Once the possible errors were detected in the process, the participants were asked to offer solutions to the problems, opening a debate that sought the adoption of agreement proposals, which were finally noted down. We encouraged the participants to describe only error sources.

Results

The analysis of the preanalytical phase, as we previously stated, revealed six sub-processes: analytical request and request form, appointment system, patient preparation, sampling, transport, and reception - preparation of samples. As it was described in the Materials and methods section, we encouraged the participants to describe only the error sources. So as to better understand the process, the area in which it is located, described above, is included between brackets next to each possible error source.

In LAB1, 24 potential errors were detected: 15 out of the laboratory facilities, and 9 within the same.

The highest RPN was 384 for two potential errors sources (existence of two request notes for a patient [analytical request and request form] and the segregation of urgent samples from the oncology service [reception - preparation of samples]). The most commented effect was the delay in processing samples or non-performance of the tests requested.

In LAB2, 16 potential errors were detected, 12 of them out of the laboratory facilities. The most commented aspect was the need to request a new sample. The highest RPN was 576, and it was given to the lack of information in patients with oral glucose overload test (patient preparation).

The actions proposed are focused on the revision of protocols, the improvement of the organization charts and the widening of information by means of establishing or improving communication ways and developing specific training programmes. All data are shown in Tables 1 and 2Table 2.

Table 1

Healthcare Failure Modal Effects Analysis data from Hospital Universitario Virgen de la Victoria Laboratory (LAB1)

Element / Function* Failure Mode Effect RPN Proposed actions
Paper Analysis Request (1) Bad quality request form
Incorrect completion
Bar code identification not read
Sample not processed 60
96
Specific training
Bar code identification on the back of the forms
Analysis Request with Electronic form (1) Request not approved or authorised analysis
Mistakes in request form
It might be done not approved or unauthorised analysis or correct test might be rejected 118 Information circuits improvement
Correcting lack of information
Revision of filters in Electronic form generation
Laboratory Information System data input (1) Not activation of patient request form (bar code not read) Sample not processed 32
Only in paper request form: two petitions one patient (double request form, one by General Practitioner, one by Clinical Specialist) Sample not processed (overlap request) 384 Protocols dissemination improvement. Surveillance of sampling
Lack of information or request not legible Sample not processed 32
Mistake in patients demographic data Sample not processed 32
Delay in scanning paper forms Delay in testing 36
Appointment (2) Misinformation to patients (fasting time, medication, etc.) Error in fasting time or any other preparation 108 Patient information improvement
Preparation control in the Electronic form generation
Error in urine samples which needs previous preparation Bad or erroneous test 64 Preparation control in the Electronic form generation
Containers delivery follow-up
Sampling (4) Double utilization of labels Electronic form: change bar code
Paper request form: Sample rejected
6
18
Early detection
Label/sample identification does not match New sample 210 Potentially serious error. Extreme identification control
Wrong test tube Sample not processed. New sample 16 Special tests obtained only in Laboratory Sampling Room
Bad quality in samples Sample not processed (risk of misdiagnosis) 90 Improving training
Incorrect patient identification Sample processing error 180 Positive patient identification
Transport (5) Delay Bad quality of samples (new sample) 49 Redesigning collection and delivery routes
Cold chain break Bad quality of samples (new sample) 72 Extreme control of devices
Loss of samples New sample 16
Delivery at the wrong destination Delay in samples processing
Samples not processed
8 Increasing information
Element / Function* Failure Mode Effect RPN Proposed actions
Samples receipt (6) Loss of sample tubes Sample not processed 81 Improving delivery area control
Bad centrifugation of samples Samples not processed 81 Improving delivery area control
Error in decantation or cold chain Incomplete analysis or sample not processed 192 Coordination between delivery area and administrative section
Aliquoting (6) Not enough samples Not processed. Gives error MI 200 Information Coordination in/at AP
Oncology urgent samples segregation Delay in the reports generation 384 Protocols improvement and information enhancing
*Parts of preanalytical phase: (1) Analytical request and request form; (2) Appointment system; (3) Patient preparation; (4) Sampling;
(5)Transport; (6) Reception and samples preparation.*RPN - Risk Priority Number.
Table 2

Healthcare Failure Modal Effects Analysis data from Hospital Universitario Juan Ramón Jiménez (LAB2)

Element / Function Failure Mode Effect RPN* Proposed actions
Analysis Request with Electronic form (1) Bad quality request form
Incorrect completion
Bar code identification not read
New sample 36 Check printers and bar codes
Incidence notification
Paper Analysis Request (1) Two patients with the same bar code
It is no possible to read the form
Relevant information not included (i.e. diuresis)
Possible incorrect result assignation
Erroneous test scheduling
Results will not be calculated
240
35
35
Redesign organisation
Increase training and awareness (video, etc.)
Patients preparation (3) Misinformation to patients (fasting time, medication, etc.), usually in appointments made by “Salud Responde” Altered results 360 Coordination between PCC, laboratories and “Salud Responde”
Sampling (4) No sample or inadequate tube
Tube without bar code
Bad sampling
Lack of patient information (glucose overload test)
New sample
Sample not processed
Altered results
27
27
576
Check list made by the driver before the samples collection from the PCC
Training
Protocols revision and update
Transport (5) Non-statutory Bridges
Delay from sampling to laboratory more than 2 h
Bad quality samples
Biological risk
Possible altered results
486 Statutory Bridges with time and temperature control and secondary container
Traceability sheets
Samples receipt (6) Loss of tubes
Bad centrifugation
Delivery at the wrong destination
New sample
Bad quality samples
Not necessary or inadequate test made
81
8
245
192
Complete traceability follow-up
Ensure the periodical revision in pre-analytical material (centrifuges, etc.)
Training and protocols revision
Specimen identification at origin
*Parts of preanalytical phase: (1) Analytical request and request form; (2) Appointment system; (3) Patient preparation; (4) Sampling; (5) Transport; (6) Reception and samples preparation. Telematic assistance given by the Andalusian Health Service, both by telephone and by electronic means. RPN - Risk Priority Number. PCC - primary care center.

With reference to the content of the tables, there is a difference in the content of the ELEMENT / FUNCTION column between both aspects, as the data provided by the laboratories were not the same: the undetected problems were not reported and, subsequently, not included, and some results can be observed in one of the laboratories and not in the other one.

Discussion

Risk management is an essential part of the quality culture in healthcare and necessarily implies a deep involvement of the professionals. In this sense, the HFMEA has proven to be, for years and in several fields, a reliable tool for the detection of possible error sources in structured systems, performing proactive risk management, an early identification of the causes of errors, and then, facilitating corrective actions (18, 19). In this sense, the value of RPN helps prioritize procedures and strategies against the errors sources detected (10).

The results obtained in both centers have more similarities than differences, although it is necessary to specify that these differences may give greater value to the study due to the different characteristics of the corrective actions and the different approaches they require.

In particular, LAB1 considered as the most important errors those detected in the implementation of a new procedure (urgent oncology samples obtained in PCC) and the existence of duplicate requests, doubtlessly due to the novelty of the process and the communication errors detected in its implementation. In addition, LAB1 also considered factors such as the co-existence of general practitioner and specialist requests (both RPN 384) together with the lack of coincidence between the patients’ identification data and the labelled samples (RPN 210) and the existence of insufficient samples that prevent errors when aliquoting a sample (RPN 200). On its part, LAB2 highlighted the deficit of information given to the patient recipient of an oral overload of glucose (RPN 576), the delay in the transport of the samples to the laboratory (RPN 486), and the possible existence of the same code for two different patients (RPN 240). The rest of the data were very similar in both centers.

It is necessary to point out findings such as different RPN compared with other studies previously published made in our work environment (12). The reason might be that the participants declared high levels of error detection (that is, low detection rate), so this, doubtlessly, decreased the values of the parameter.

Although most error sources may be detected, a risk of misdetection still exists, as we previously commented. This situation forces us to plan strategies and actions that allow us to manage this problem as better as possible.

The data obtained from the HFMEA are very similar to those from the SWOT (Strengths, Weakness, Opportunities, and Threats) analysis previously performed by our team (19, 20). Thus, we have to keep in mind that asking professionals has proved to be a useful practice, as could be seen when asked to give their opinions. This information provides enhancement strategies as it comes directly from those involved in the studied process. In this sense, the suggestions made by the laboratory staff were mainly focused on scheduling a specific training programme and also a deep revision of the existing protocols, which are relatively easy suggestions to perform. This is why we drafted a detailed report for the management team with instructions to carry out a detailed planning of activities in the near future.

Aknowlegdments

This paper was granted by funds from the Fondo de Investigaciones Sanitarias (FIS, Spanish Health Ministry) PI 12/1099 and Fundación Progreso y Salud, (FPS) Andalusian Regional Health System PI 14/0509.

Notes

[1] Conflicts of interest None declared.

References

1 

Gómez Salgado J, Romero Ruiz A, Camacho Bejarano R. Relevancia de las enfermeras en los errores en la fase preanalitica: su relación con la seguridad del paciente. Rev Rol Enferm. 2014;37:662–6. [in Spanish]

2 

[Estudio APEAS Estudio sobre la seguridad de los pacientes en atención primaria de salud. Informes, estudios e investigación.] Madrid. Ministerio de Sanidad y Consumo. 2008. [in Spanish]

3 

Plebani M, Carraro P. Mistakes in a stat laboratory: types and frequency. Clin Chem. 1997;43:1348–51.

4 

Bonini P, Plebani M, Ceriotti F, Rubboli F. Errors in laboratory medicine. Clin Chem. 2002;48:691–8.

5 

Romero A, Muñoz M, Ramos JR, Campos A, Ramírez G. Preanalytical mistakes in a stat laboratory. Clin Chem Lab Med. 2005;43:974–5. https://doi.org/10.1515/CCLM.2005.168

6 

Carraro P, Plebani M. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem. 2007;53:1338–42. https://doi.org/10.1373/clinchem.2007.088344

7 

Romero A, Cobos A, López-León A, Ortega G, Muñoz M. Preanalytical mistakes in samples from primary care patients. Clin Chem Lab Med. 2009;47:1549–52. https://doi.org/10.1515/CCLM.2009.338

8 

Donaldson L. Foreword. Clin Chem Lab Med. 2007;45:697–9. https://doi.org/10.1515/CCLM.2007.171

9 

Lippi G, Guidi GC. Risk management in the preanalytical phase of laboratory testing. Clin Chem Lab Med. 2007;45:720–7. https://doi.org/10.1515/CCLM.2007.167

10 

Bestratén Bellovi M, Orriols Ramos R, Mata París C. [Análisis modal de fallos y efectos. AMFE. Notas técnicas de prevención.] Madrid. Instituto Nacional de Higiene y Seguridad en el Trabajo. Ministerio de Trabajo. 2004. [in Spanish]

11 

DeRosier J, Stalhandske E, Bagian JP, Nudell T. Using Health Care Failure Mode and Effect Analysis: The VA National Center for Patient Safety’s Prospective Risk Análisis System. Joint Commission on Accreditation of Healthcare Organizations; 2002.

12 

Giménez Marín A, Molina Mendoza P, Ruiz Arredondo JJ, Acosta González F, López Pérez M, Jiménez Cueva M, et al. [Aplicación del análisis modal de fallos y sus efectos a la fase preanalítica de un laboratorio clínico.] Rev. Lab Clin. 2010;3:161–70. [in Spanish]

13 

Giménez-Marín A, Rivas-Ruiz F, Pérez-Hidalgo MM, Molina-Mendoza P. Pre-analytical errors management in the clinical laboratory: a five-year study. Biochem Med (Zagreb). 2014;24:248–57. https://doi.org/10.11613/BM.2014.027

14 

Söderberg J, Brulin C, Grankvist K, Wallin O. Preanalytical errors in primary healthcare: a questionnaire study of information search procedures, test request management and test tube labelling. Clin Chem Lab Med. 2009;47:195–201. https://doi.org/10.1515/CCLM.2009.048

15 

Romero A, Cobos A, Gómez J, Muñoz M. Role of training activities for the reduction of pre-analytical errors in laboratory samples from primary care. Clin Chim Acta. 2012;413(1-2):166–9. https://doi.org/10.1016/j.cca.2011.09.017

16 

Burr JT. The Tools of Quality. Part VI. Pareto Charts. Qual Prog. 1990;23:59–61.

17 

Astier Peña MP, Maderuelo Fernández JM, Jiménez Julvez MT, Martín Rodríguez MD, Palacio Lapuente J, Oliveras Cañada G. [Análisis proactivo del riesgo: el análisis modal de fallos y efectos (AMFE) Revista Clínica Electrónica de Atención Primaria 2010.] Available at: http://ddd.uab.cat/pub/rceap/rceap_a2010m10n18/rceap_a2010m10n18a7.pdf. Accessed August 12th 2015. [in Spanish]

18 

Delgado Silveira E, Álvarez Díaz A, Pérez Menéndez-Conde C, Serna Pérez J, Rodríguez Sagrado MA, Bermejo Vicedo T. [Análisis modal de fallos y efectos del proceso de prescripción, validación y dispensación de medicamentos.] Farmacia Hospitalaria 2012;36:24-32. [in Spanish] https://doi.org/https://doi.org/10.1016/j.farma.2010.12.002

19 

Gómez-Salgado J, Romero Ruiz A, Caparrós IS, Reina M, Ruiz-Frutos C. Preanalytical errors: a preliminary approach to the point of view of primary care care givers. Clin Chem Lab Med. 2015;53:225–9. https://doi.org/10.1515/cclm-2014-0576

20 

Gómez-Salgado J, Romero A, Cobos A, Caparrós IS, Gómez-Fernández JA, Domínguez JA, et al. Preanalytical errors: the professionals’ perspective. Clin Chem Lab Med. 2014;52:e53–5. https://doi.org/10.1515/cclm-2013-0930